Q. How would you clean a 3 cu ft V blender?
A: I recommend using a 0.5% Solujet® solution of 12 L to clean the 3 cu ft V blender followed by 2 rinses and then a 3rd sampling rinse. You may wish
How do you determine optimum detergency for Liquinox detergent? As a general statement, optimum detergency is reached at a 1-2% concentration (optimum defined as amount of soil removed per unit of detergent used). Maximum detergency is typically reached at a…
Several times when we have dropped the tablets in the bottom before the basket of pipettes it has shot out the siphon whole! Any advice? It can be solved by following a procedural change….
Q. I am now using Tergajet with 0.5% concentration. I prepare it with ambient water and after preparation, I left it for one week. I’m not sure, is this method is okay or not?
A. You are correct that the shelf life of diluted detergent solution life is something to be monitored. While the shelf life of Tergajet®
Q. What is the proper way to rinse after using Alconox detergents?
A. In pharmaceutical cleaning, running water rinse for at least 10 seconds on each surface is desirable. Not all rinse water is created equal. Learn More.
Not finding what you need?
For further assistance please fill out the form at Ask Alconox or email us at cleaning@alconox.com.