Q. Our pharmaceutical company is transferring product manufacture to a different one our facilities. We used a CIP cleaning process with Citrajet and are going to have to perform validation and verification tests again. What information do we need for our testing? Chemical properties might be helpful as well as the science on how this chemical works. We would also need information on disposal and the requirements for allowing this to flow to normal process drains.
P20 is a low carbon mold steel and can be safely cleaned with an acidic detergent, which excels at removing inorganic residues like salts and oxidation.
Do you have a known solution for removing erythrosine from stainless steel? Erythrosine is also known as Red 3 when used as a cosmetic. Sometimes the cleaning is manual, other times it is automated.
A: A two-step cycle with a base followed by an acid, whether it be CIP cleaning or in a large scale liquid dispensing system washer, is a robust and, when needed, is a recommended process. Water spots typically occur because of two main mechanisms….
Q. We are washing stainless medical devices in a washer and are getting water spots. We are using Solujet and Citrajet. What’s causing this problem?
A. Water spots typically occur because of two main reasons: the orientation of the parts in the washer is trapping dirty wash water and/or detergent dosing is insufficient.
Before we get started, what's your email address?